Search This Blog

Working principle of slow wire processing

 Slow wire walking, also called low-speed wire walking, is a kind of CNC machining machine tool that uses continuously moving fine metal wire as an electrode to pulse spark discharge on the workpiece to generate a high temperature of over 6000 degrees, ablate metal and cut into a workpiece. The principle of wire processing is the phenomenon that there is a gap between the wire electrode and the workpiece, and the metal is removed by continuous discharge. Since the slow-moving wire cutting machine adopts the method of wire electrode continuous feeding, that is, the wire electrode is processed during the movement, so even if the wire electrode is worn out, it can be continuously supplemented, so it can improve the machining accuracy of the parts and slow the wire. The surface roughness of the workpiece processed by the cutting machine can usually reach Ra=0.8μm and above, and the roundness error, linear error and dimensional error of the slow-moving wire cutting machine are much better t

Hydrostatic guideway of CNC machining lathe

The static pressure slide rail (TTW guide) of the CNC machining lathe transfers the oil with a certain pressure through the throttle to the oil cavity between the sliding surfaces of the slide rail (TTW guide) to form a pressure oil film to float the moving parts , Make the sliding rail (TTW guide) surface in a pure liquid friction state.   CNC machining General CNC machining usually refers to computer digital control precision machining, CNC machining lathe, CNC machining milling machine, CNC machining c17200   beryllium   copper   and milling machine, etc. The feed route of finishing is basically carried out along the part contour sequence. Therefore, the focus of determining the feed route is to determine the feed route of rough machining and idle stroke. In the numerical control processing, the control system issues instructions to make the tool perform various motions that meet the requirements, and the shape and size of the workpiece are expressed in the form of numbers and lette

Introduction of KOVAR parts

KOVAR parts are commonly used as metal casing materials in the electronic packaging industry. Because they have a linear expansion coefficient close to that of molybdenum group glass, and can produce less sealing stress during the sealing (melting) process with molybdenum group glass, so To obtain good air-tightness, in order to make the metal tube and shell to achieve air-tight sealing, in the entire sealing process, the annealing process undoubtedly plays an important role as a link between the previous and the next. The internal stress generated during KOVAR  machining also prepares the material structure for the implementation of the subsequent process-the sealing process of the metal parts. The main purpose of annealing Kovar shell before sealing is to: (1) Eliminate machining stress. When Kovar undergoes plastic machining deformation during cold working, about 10% to 15% of the applied energy is converted into internal energy, which is commonly referred to as internal stress,

Mitsubishi FX3G-2AD-BD

Mitsubishi FX3G-2AD-BD
#FX3G-2AD-BD Mitsubishi FX3G-2AD-BD New M3×8 tapping screws for installation: 2 pcs. • Side cover • Installation Manual (This manual), FX3G-2AD-BD pictures, FX3G-2AD-BD price, #FX3G-2AD-BD supplier
-------------------------------------------------------------------
Email: sales@shunlongwei.com

-------------------------------------------------------------------
The FX3G-2AD-BD boards for analog input (hereinafter called 2AD-BD) is an expansion boards to add two analog input points.
Attention
This product is designed for use in industrial applications.
Caution for EC Directive
The analog expansion boards have been found to be compliant to the European standards in the aforesaid manual and directive. However, for the very best performance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered carefully. For users of proprietary cables (integral with sensors or actuators), these users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other EMC protection is provided, then users may experience temporary loss or accuracy between ±10 % in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are followed for the users complete control system, users should expect accuracy as specified in this manual.
• Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling. Where possible users should run analog cables separately.
• Good cable shielding should be used. When terminating the shield at Earth - ensure that no earth loops are accidentally created.
• When reading analog values, EMC accuracy can be improved out by averaging the readings. This can be achieved either through functions on the analog expansion boards or through a users program in the PLC main unit.

M3×8 tapping screws for installation: 2 pcs. • Side cover • Installation Manual (This manual)

Contact Us


Get In Touch or Get A Quote

Need an expert? you are more than welcomed to
leave your contact info and we will be in touch shortly
YOUR COMPANY
Sifangyuan Industrial Park, Xinshapu, Huaide Community
Humen town, Dongguan City, Guangdong Province. 
860769-82886112